| The
small-size of this phantom makes it highly
portable for convenient QC testing. The
unique configuration eliminates the need
for multiple holes and plugs. |
|
|
|
|
|
|
The
EZ-Cube Phantom with Chamber Positioning
Inserts |
|
2 ea 3.0cm
thick |
|
|
1 ea 2.5cm
thick |
|
1 ea 2.0cm
thick |
|
2 ea 1.0cm
thick |
|
1 ea 0.5cm
thick |
| |
|
 |
The
Reinstein EZ-Cube
showing the exchangeable inserts placed
within the phantom's cavity. The chamber
can be placed at reproducible depths within
the phantom without the necessity to move
or disturb the phantom.
|
| *pre-drilled
for FARMER CHAMBERS |
| |
|
Technical
Specifications: |
| Material Used:
|
UHMW |
Overall Weight: |
3.7kg |
Height: |
15cm |
Width: |
15cm |
Length: |
15cm |
| |
Adjustable
Leveling feet and Bubble Level.
|
|
| |
Custom
Fabrication: |
| For your convenience,
the EZ-Cube phantom's insert can
be custom-drilled to accept other
chamber types. Just supply the model
number and diameter of the chamber
you will be using. |
|
|
 |
|
| |
| The
Reinstein EZ -Cube Phantom |
 |
from MRNI, Inc. is
a radiation oncology QA phantom that
provides rapid and reproducible Ion
chamber positioning from 1cm to 12cm
depth at 0.5cm intervals. Its unique
design allows placement of the Ion chamber
through a range of depths, without ever
having to readjust the phantom position
with respect to the central axis or
its TSD. Conventional solid "slab"
phantoms often require realignment of
the slabs for each change in Ion chamber
depth. This can waste substantial amounts
of time and lead to misalignment, especially
during monthly QA (as recommended by
AAPM TG-40) of a dual-photon, multiple-electron
beam accelerator.
The Reinstein EZ-Cube phantom is designed
to simplify testing of beam output plus
energy constancy at three gantry angles:
90°, 180°, 270°, as described
in "Comprehensive QA for Radiation
Oncology: Report of AAPM Radiation Therapy
Committee Task Group 40."
|
|
|
Features |
|
 |
| |
Output constancy
measurements for photon and electron
beams |
| |
Depth dose constancy
measurements for photon and electron
beams |
| |
Superior phantom
alignment stability and Ion chamber
positioning reproducibility |
| |
Rapid, precise
and reproducible Ion chamber depth
changes (from 1cm to 12cm depth
at 0.5cm intervals) while maintaining
constant TSD. |
| |
Easily readable
and unambiguous Ion chamber depth
scale. |
| |
Output plus depth
dose constancy measurements at 90°,
180°, 270° gantry angles. |
|
|
One phantom setup
for all output and energy constancy
measurement depths. |
|
|
Reduction of total
setup and measuring times by as
much as 75%. |
|
|
Includes adjustable
support leveling legs and a bubble
level. |
|
 |
Advantages |
|
|
Simplifies
testing of output versus
gantry angel, which is difficult
to accomplish by other phantoms. |
| |
Provides
rapid and reproducible Ion
chamber positioning at 0.5cm
steps, without the annoying
need for repeated readjustment
of phantom position. |
| |
Eliminates
the need to periodically
recalibrate or balance detectors
... a significant hidden
expense with multiple detector
systems. |
| |
Is a multipurpose,
cost-saving QA and calibration
phantom that makes use of
your own Ion chamber and
electrometer. |
| |
Verifies
every constancy measurement
for photon and electron
beams. |
|
| |
|
|