Reinstein EZ - Cube Phantom - Catalog # 0402
The Reinstein EZ - Cube Phantom
Delivers Fast, Easy and Accurate Output Depth Dose Constancy Measurements for Photon and Electron Beams in Accordance with AAPM TG-40 Guidelines.
The Reinstein EZ-Cube Phantom Provides a Means for Quickly and Accurately Changing Ion Chamber Depth Without the Need for Realignment Between Measurements !
The small-size of this phantom makes it highly portable for convenient QC testing. The unique configuration eliminates the need for multiple holes and plugs.
 
The EZ-Cube Phantom with Chamber Positioning Inserts
 
2 ea 3.0cm thick
 
1 ea 2.5cm thick
 
1 ea 2.0cm thick
 
2 ea 1.0cm thick
 
1 ea 0.5cm thick
   
The Reinstein EZ-Cube
showing the exchangeable inserts placed within the phantom's cavity. The chamber can be placed at reproducible depths within the phantom without the necessity to move or disturb the phantom.

*pre-drilled for FARMER CHAMBERS
 
Technical Specifications:
Material Used:
UHMW
Overall Weight:
3.7kg
Height:
15cm
Width:
15cm
Length:
15cm
 
Adjustable Leveling feet and Bubble Level.
 
Custom Fabrication:
For your convenience, the EZ-Cube phantom's insert can be custom-drilled to accept other chamber types. Just supply the model number and diameter of the chamber you will be using.
The Reinstein EZ -Cube Phantom
from MRNI, Inc. is a radiation oncology QA phantom that provides rapid and reproducible Ion chamber positioning from 1cm to 12cm depth at 0.5cm intervals. Its unique design allows placement of the Ion chamber through a range of depths, without ever having to readjust the phantom position with respect to the central axis or its TSD. Conventional solid "slab" phantoms often require realignment of the slabs for each change in Ion chamber depth. This can waste substantial amounts of time and lead to misalignment, especially during monthly QA (as recommended by AAPM TG-40) of a dual-photon, multiple-electron beam accelerator.

The Reinstein EZ-Cube phantom is designed to simplify testing of beam output plus energy constancy at three gantry angles: 90°, 180°, 270°, as described in "Comprehensive QA for Radiation Oncology: Report of AAPM Radiation Therapy Committee Task Group 40."
Features
 
Output constancy measurements for photon and electron beams
 
Depth dose constancy measurements for photon and electron beams
 
Superior phantom alignment stability and Ion chamber positioning reproducibility
 
Rapid, precise and reproducible Ion chamber depth changes (from 1cm to 12cm depth at 0.5cm intervals) while maintaining constant TSD.
 
Easily readable and unambiguous Ion chamber depth scale.
 
Output plus depth dose constancy measurements at 90°, 180°, 270° gantry angles.
 
One phantom setup for all output and energy constancy measurement depths.
 
Reduction of total setup and measuring times by as much as 75%.
 
Includes adjustable support leveling legs and a bubble level.
Advantages
 
Simplifies testing of output versus gantry angel, which is difficult to accomplish by other phantoms.
 
Provides rapid and reproducible Ion chamber positioning at 0.5cm steps, without the annoying need for repeated readjustment of phantom position.
 
Eliminates the need to periodically recalibrate or balance detectors ... a significant hidden expense with multiple detector systems.
 
Is a multipurpose, cost-saving QA and calibration phantom that makes use of your own Ion chamber and electrometer.
 
Verifies every constancy measurement for photon and electron beams.
Mick Radio-Nuclear Instruments, Inc.
521 Homestead Ave.
Mount Vernon, NY 10550
Toll Free #: (877) 597-MRNI
Phone: (914) 667-3999
Fax: (914) 665-8834
Email:
Shipping and Receiving:
518 S. Columbus Ave.
Mount Vernon, NY 10550
Peter A. Reed, Sales Representative
256 Randall Avenue
Freeport, New York 11520
Cell: (516) 972-2752
Fax: (516) 546-4753
E-mail: