Perma-Doc Phantom - Catalog # 9404
COMPATIBLE WITH VariSource® / MicroSelectron® / GammaMed® HDR Afterloading Systems.
The “PermaDoc Phantom” is shown with the permanently embedded tungsten wire centimeter scale and removable 3mm diameter tandems.
" Your Daily Quality Assurance performed with Ease and Confidence! "
Features:
 
Verifies Source Positioning and Stepping Accuracy
 
Images Centimeter Scale Directly on Film
 
Requires Single Exposure Only
 
Set-up Accomplished in Seconds
 
Eliminates All Guess-Work
 
Precision Built
 
Compatible with All HDR Units
 
Fulfills Documentary QA Requirements

For compatibility to other HDR afterloading systems, unit-specific tandems are utilized.
Description:
The "PERMA-DOC PHANTOM" provides the necessary PERMANENT documentation required by the NRC's new and stringent quality assurance tests associated with HDR. The PERMA-DOC PHANTOM, with its centimeter scale automatically transferred to the film by fluorescent radiation, readily identifies up to 20 source positions and their stepping accuracy. Two matching 3/8" plexi plates allow for insertion of a 10" x 12" ready-pack V-film. The film is exposed by the HDR Ir-192 source with dwell times of I second over a maximum of 20 positions spaced 1 cm apart. The resulting film displays the source images superimposed on the image of the centimeter scale.
Source Images Superimposed on the Image of Centimeter Scale!
Shown is part of the V-film exposed with an HDR Ir-192 source for dwell times of I second over a distance of 20cm. Source position and stepping accuracy are verified by scale lines that pass exactly through the centers of the corresponding source images. Most importantly, the first two distally located markers are spaced such as to represent the distance from tip of tandem to center of active source. For example: Tip of tandem to center of source for the GammaMed 12i sources is 3.75mm, i.e., separation of the first two tungsten wires is 3.75mm. With the incorporation of the distal marker wire, the necessity to prick a hole into the film is therefore eliminated.
Mick Radio-Nuclear Instruments, Inc.
521 Homestead Ave.
Mount Vernon, NY 10550
Toll Free #: (877) 597-MRNI
Phone: (914) 667-3999
Fax: (914) 665-8834
Email:
Shipping and Receiving:
518 S. Columbus Ave.
Mount Vernon, NY 10550
Peter A. Reed, Sales Representative
256 Randall Avenue
Freeport, New York 11520
Cell: (516) 972-2752
Fax: (516) 546-4753
E-mail: